The following sections of the International Residential Code as adopted in LMC 14.04.010 are amended to read as follows:

R 105.2 Work exempt from permit.

Building, Item #1 amended. One-story detached accessory structures used as tool and storage sheds, playhouses, and similar uses provided the floor area does not exceed two hundred square feet.

Table R301.2(1), Climatic and Geographic Design Criteria, to be filled-in as follows:

Ground Snow Load: 25 psf

Wind Speed (mph): 85

Seismic Design Category: D1

Subject to Damage From

Weathering: Moderate

Frost Line Depth: 12"

Termite: Slight to Moderate

Decay: Slight to Moderate

Winter Design Temp.: 17° F

Ice Shield Underlayment Req.: No

Air Freezing Index: N/A

Mean Annual Temperature: 50° F

(Ord. 1467 §4, 2015; Ord. 1371 §4, 2011; Ord. 1225 §3, 2004; Ord. 1208 §14, 2003).