Site plan review and binding site plan approval may be given for projects proposed to contain one building greater than two hundred thousand square feet but not more than five hundred thousand square feet; provided the following site and design standards are met:

A. The site shall consist of a parcel or contiguous parcels totaling a minimum of forty acres.

B. Existing buildings retained within a six-month, one-year or five-year zone of a wellhead protection area shall be transferred from septic systems to public sewers within twenty-four months after approval of the first building permit unless otherwise provided for by a development agreement.

C. To reduce the displacement of existing small and medium sized businesses the applicant shall enter into a development agreement that identifies an area consisting of no less than five contiguous acres where the existing buildings would be initially retained until a later redevelopment phase of the project subject to the following standards:

1. Future redevelopment within this area shall be designed to incorporate multiple buildings and/or one or more multi-tenant buildings to create spaces of varying size which are intended for a mix of small to medium size businesses.

2. Where this redevelopment area abuts a major transportation corridor (e.g., Marvin Road), the redevelopment shall create a transition in building sizes that reduce the scale and intensity of adjacent buildings greater than two hundred thousand square feet, and incorporate setbacks and landscaping along the frontage that is consistent with that corridor.

D. When uses identified in LMC 16.39.020(A) will be adjacent to a residential zoned property (LD, MD or HD), or an open space institutional zoned property (OSI), the minimum yard setback between the residential or open space institutional zone shall be fifty feet and include a twenty-foot Type I landscaping buffer as defined in LMC 16.80.050(B). Provided, however, that these uses are separated from a residential or open space institutional zone by commercial development, the required buffer shall be fifteen feet and include at least an eight-foot Type II landscaping buffer as defined in LMC 16.80.050(B).

E. Truck bay doors and/or loading or unloading areas shall not face residential zoned property (LD, MD or HD), if within two hundred fifty feet of said zones, unless separated by the placement of a building without bay doors or landscape or other screening that reduces visual and noise impacts.

F. When adjacent to a residential zoned property (LD, MD or HD), a noise study shall be performed to demonstrate that the proposed use can comply with the maximum noise limits established by LMC 16.57.030 and Chapter 173-60 WAC.

G. Site design shall incorporate a mix of landscaping, berms, fencing, building setbacks, and/or other site design elements to establish internal transitions between light industrial and commercial uses within the master site plan which reduce visual and noise impacts created by truck movements, loading and unloading.

H. Truck access and circulation shall be designed to reduce or restrict the travel of truck traffic through residential areas. Such measures may include, but not be limited to, median controls, signage, driveway design, and internal circulation. All methods are subject to approval by the city of Lacey community development and public works departments.

I. New commercial and industrial buildings shall be consistent with the applicable city of Lacey design review standards found in LMC 14.23.082 for commercial buildings and LMC 14.23.083 for industrial buildings.

J. When a site is adjacent to a residential zone, the applicant shall hold a neighborhood meeting to provide information on the proposed development. Notice of the meeting shall be sent by mail to all property owners within three hundred feet, as well as to adjacent homeowners’ associations or neighborhood groups within the radius. (Ord. 1576 §2, 2021).