1. The noise limitations established are as set forth in the following table after any applicable adjustments provided for herein are applied.
EDNA OF NOISE SOURCE |
EDNA OF RECEIVING PROPERTY |
||
---|---|---|---|
CLASS A |
CLASS B |
CLASS C |
|
CLASS A |
55 dBA |
57 dBA |
60 dBA |
CLASS B |
57 |
60 |
65 |
CLASS C |
60 |
65 |
70 |
2. Between the hours of 10:00 p.m. and 7:00 a.m. the noise limitations of the foregoing table shall be reduced by 10 dBA for receiving property within Class A EDNAs.
3. At any hour of the day or night the applicable noise limitations in (1) and (2) above may be exceeded for any receiving property by no more than:
a. 5 dBA for a total of 15 minutes in any one-hour period; or
b. 10dBA for a total of 5 minutes in any one-hour period; or
c. 15 dBA for a total of 1.5 minutes in any one-hour period.